2014 High Quanlity Multi Parameter  Patient Monitor
Next

2014 High Quanlity Multi Parameter Patient Monitor

FOB Price

Get Latest Price

0 ~ 550

|

1 Set Minimum Order

Country:

China

Model No:

YM-9000

FOB Price:

0 ~ 550 Get Latest Price

Place of Origin:

China

Price for Minimum Order:

-

Minimum Order Quantity:

1 Set

Packaging Detail:

-

Delivery Time:

2-7 days after receiver payment

Supplying Ability:

10000 Set per Month

Payment Type:

T/T, Western Union

Product Group :

Contact Now
Free Member

Contact Person Hattie

Rm. 621, Bldg. D1, Baoti Huameiju, Baoan Dist., Shenzhen, Guangdong, China (Mainland), Shenzhen, Guangdong

Contact Now

Product Specification

  • Type:Patient Monitor
  • Lead Mode:5 Leads (R L F N C or RA LA LL RL V)
  • Lead selection:I, II, III, avR, avL, avF, V
  • Wavef orm:2 ch
  • Wave form:1 ch
  • Resolution:1 bpm
  • Standard:ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
  • Optional:Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
  • Certification:CE

Product Description

*2.1" color TFT screen 
Multi channel display 
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms



Alarm review, arrhythmia review 
Patient info. Input 
Anti defibrillation design
NIBP over pressure protection
Plug in rechargeable battery, AC/DC available. 
Supporting wire or wireless network.


Technical Specifications

ECG

Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection I, II, III, avR, avL, avF, V
Wavef orm 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL) 
Lead selection I, II, III,
Wave form 1 ch
Gain 2.5mm/mV, 5.0mm/mV, *0mm/mV,*0mm/mV, auto

HR and Alarm Range Adult *5 ~ **0 bpm
Neo/Ped *5 ~ **0 bpm
Accuracy ±1% or±1bpm, which is greater
Resolution 1 bpm 
Sensitivity > **0 (uVp-p) 
Differential Input Impedance > 5 MΩ

CMRR Monitor > **5 dB 
Operation > **5 dB 
Diagnosis > *5 dB
Electrode offset potential ±**0mV 
Leakage Current 2.5 MΩ
Measuring Impedance Range 0.3~3 Ω
Base line Impedance Range **0~4 KΩ
Bandwidth 0.1~2.5Hz
Resp. Rate Measuring and Alarm Range
Adult 0 ~ **0 Brpm 
Neo/Ped 0 ~ **0 Brpm 
Resolution 1 Brpm 
Accuracy ±2 Brpm

Apnea Alarm *0 ~ *0 S

 


NIBP

Method Oscillometric
Mode Manual, Auto, STAT 
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, *0, *5, *0, *0, *0,**0, **0, **0,**0 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range *0 ~ **0 bpm
Alarm Type SYS, DIA, MEAN

Measuring and alarm range Adult Mode
SYS *0 ~ **0 mmHg 
DIA *0 ~ **5 mmHg 
MEAN *0 ~ **5 mmHg
Pediatric Mode
SYS *0 ~ **0 mmHg 
DIA *0 ~ **0 mmHg 
MEAN *0 ~ **5 mmHg
Neonatal Mode
SYS *0 ~ **5 mmHg 
DIA *0 ~ **0 mmHg 
MEAN *0 ~ **0 mmHg
Resolution 1mmHg

Accuracy Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection Adult Mode **7±3 mmHg 
Pediatric Mode **0±3 mmHg 
Neonatal Mode **7±3 mmHg

SpO2
Measuring Range 0 ~ **0 % 
Alarm Range 0 ~ **0 % 
Resolution 1 %
Accuracy *0% ~ **0% 2 %
0% ~ *9% unspecified
Actualization intervalabout 1 Sec. 
Alarm Delay *0 Sec.
Pulse Rate Measuring and Alarm Range *0~**0 bpm
Resolution 1bpm
Accuracy ±3bpm


TEMP

Channel 2
Measuring and Alarm Range 0 ~ *0 ℃
Resolution 0.1 ℃
Accuracy ±0.2 ℃
Actualization intervalabout 1 Sec.
Average Time Constant < *0 Sec.


IBP

Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range ART 0 ~ **0 mmHg 
PA  6 ~ **0 mmHg
CVP/RAP/LAP/ICP *0 ~ *0 mmHg
P1 / P***0 ~ **0 mmHg


Press Sensor Sensitivity 5 uV/V/mmHg
Impedance **0 to ***0Ω

Resolution 1 mmHg
Accuracy ±2% or 1mmHg which is greater
Actualization interval about 1 secretary

 


Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

Country: China
Model No: YM-9000
FOB Price: 0 ~ 550 Get Latest Price
Place of Origin: China
Price for Minimum Order: -
Minimum Order Quantity: 1 Set
Packaging Detail: -
Delivery Time: 2-7 days after receiver payment
Supplying Ability: 10000 Set per Month
Payment Type: T/T, Western Union
Product Group : Patient Monitor

Send a direct inquiry to this supplier

To:

Hattie < Shenzhen Yamos Technology Co.,Ltd >

I want to know: