Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
AES-LASER Pro AES-LASER Pro AES-LASER Pro AES-LASER Pro AES-LASER Pro
Next

AES-LASER Pro

FOB Price

Get Latest Price

1 / Unit

|

1 Unit Minimum Order

Country:

China

Model No:

AES-LASER96

FOB Price:

1 / Unit Get Latest Price

Place of Origin:

China

Price for Minimum Order:

1 per Unit

Minimum Order Quantity:

1 Unit

Packaging Detail:

Aluminium case or wooden case

Delivery Time:

3-5 working days by DHL, UPS or Fedex

Supplying Ability:

888 Unit per Year

Payment Type:

Western Union, T/T

Contact Now
Free Member

Contact Person Mr. Tonic

Meilin road, Shenzhen, Guangdong

Contact Now

Product Specification

  • Brand Name: AES
  • Screen:Buttom
  • Color:White

Product Description

image
AES-LASER Pro

 

Treatment Principle

AES-LASER Pro, the laser skin treatment device treatment principle is that using the Laser selective and adjusting Q-principle laser Blasting, making the precise dose of a specific wavelength of energy aim at a particular structor in a very short period of time---colorradical: derma and epidermis of ink, carbon particles and other exogenous and endogenous pigment granules of melanin pigment cells. Pigment be heated suddenly then occur blasting, the pigment was crushed to become smaller fragments, the crushed fragments was phagocytosed by macrophages, with the macrophage cells goes into the lymphatic circulation then pigment is excreted.
 

Work condition
Environment tempreture:10~30℃;
Relative humidity:≤75%;
atmospheric pressure:860~1060hpa;
Power supply:AC220V,50Hz;
Cooling water:deionized water or distilled water

 

Whole machine functions,
Single pulse energy degree showing and adjusting
Pulse wavelenth showing and adjusting
Pulse frenquency and showing adjusting
Working condition and showing adjusting


Before and After:
image
image

 


Safety inquiry

1, the electric shock protection: Conforms to GB9706.1-2007 "Medical electrical equipment Part I: General requirements for safety" in the Class B Type I device regulations.
2, Laser Radiation Protection: Conforms to GB7247-2001 "Radiation safety of laser products, equipment classification, requirements and user's guide", the 4 types of medical laser product radiation safetyrequirements.


Indications

1 Indications,
This instrument is mainly used for eliminate some of the clinical exogenous and endogenous skin, blue,black, brown pigment lesions, such as: tattoos, tattoo, nevus of Ota and so on.

2, The treatment interval Two treatment should be about two months apart, so that the pigment particles were crushed have enough time to be absorbed.

3, Number of treatment,
Many cases, the treatment generally required to get better results, the number of specific treatment of patients with the concentration of pigment from the affected area, depth, pigment composition, each treatment using the laser dose, patients with macrophages in vivo absorption of pigment granules and other factors. Generally exogenous pigment treatment to be more than 3 times, 5 times the endogenous pigment to be more satisfactory than the treatment effect obtained a small number of patients with repeated treatment effect is not satisfactory.

Before and After: 
image


Contraindications
1. For patients with dark skin, we suggest they take treatments after skin-whitening. Otherwise the skin maybe hurt slightly.
2. After the treatment, the skin will become red and swollen or blood infiltrated, if so, patients can ice the treatment skin or apply some ointment against scar.
3. Some metal ion such as ferric ion will become chemical substance, if so the skin will be darker after treatment. It is not the problem of machine self.
4, after the treatment skin should be kept clean and dry to avoid infection.
5 Postoperative Results boil, should make it off on their own in order to avoid man-induced scars.
6, Repeating treatment is prohibited in the same area, or tissue will be damaged due to heat accumulation.

 

Application: 
A. Removal endogenous pigment: Nevus of Ota, coffee spot, age pigment, freckle etc.
B. For exogenous pigment: Tattoo of body, eyeline and eyebrow. 
C. Skin whitenning .
D. Remove striae gravidarum.

image

Technical specifications: 

Lasertype

Q-swiched ND: YAG

Wavelength 1064nm/532nm
Pulse Energy 400mJ-800mJ Maximum output energy density 15mJ/cm2
Pulse Duration 10ns Pulse rate 1-5Hz
Cooling system Water cooling Power AC220v/50Hz/110v/60Hz
Netweight 8kg Dimension

37cm(L)× 26cm(W)× 26cm(H) 

 

Country: China
Model No: AES-LASER96
FOB Price: 1 / Unit Get Latest Price
Place of Origin: China
Price for Minimum Order: 1 per Unit
Minimum Order Quantity: 1 Unit
Packaging Detail: Aluminium case or wooden case
Delivery Time: 3-5 working days by DHL, UPS or Fedex
Supplying Ability: 888 Unit per Year
Payment Type: Western Union, T/T
Product Group : Q-switched Nd yag laser

Related Products AES TECHNOLOGY CO., LTD

Send a direct inquiry to this supplier

To:

Mr. Tonic < AES TECHNOLOGY CO., LTD >

I want to know: