Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Barium Hydroxide 99%
Prev
Barium Hydroxide 99%
Next

Barium Hydroxide 99%

FOB Price

Get Latest Price

699 / Metric Ton

|

100 Ton Minimum Order

Country:

China

Model No:

Barium Salt Series

FOB Price:

699 / Metric Ton Get Latest Price

Place of Origin:

-

Price for Minimum Order:

699 per Metric Ton

Minimum Order Quantity:

100 Ton

Packaging Detail:

Professional Package: 25kg/pp bag.

Delivery Time:

Within 25 Days After Received the L/C or the Depos

Supplying Ability:

3000 Metric Ton per Month

Payment Type:

L/C, T/T

Product Group :

Contact Now
Free Member

Contact Person williams

Muping, Sichuan

Contact Now

Product Specification

Product Description

 
 
1.Barium Hydroxide *9%
2.Content: *9% Min
3.Reliable Manufacturer
4.Competitve Freight
5.COA, MSDS

 

Zigong Gold Way International Ltd, which was founded in ***7, the leading base of barium chloride & the chemical products supplier in South-West of China, deals with chemical product production and domestic & foreign trade.

The company, fixed assets RMB *6 million Yuan, possesses a research centre and five production bases.

We pay a great attention to clerks value, develops its undertaking with good humanities environment and cultures.

Our running principles are sharing all resources, credible, harmonious, and developments.

We sincerely welcome the old and new friends to our company.

Factory:

 

Production Equipment:

Production Field:

Package&Transportation:

Basic information:

 

Product Name: Barium Hydroxide *9%

 

Type: Barium Series

 

Property: Colorless Transparent Crystal, White powder

 

 

Sort Application: Inorganic Chemical Products: Inorganic Alkali

 

 

Risk Category: 6.1

 

 

CAS No.: *********6

 

EINECS No.: ********5

 

National No.: ****1

 

HS Code: *******0

 

UN No.: ***4

 

Molecular Formula: Ba (OH)2

 

Molecular Weight: **1.*5

 

Melting Point: **0°C

 

Relative Density: 2.**8(*6°C)

 

Refractive Index: 1.**1

 

Stability: Stable

 

Toxic: Highly toxic

 

Catabolite: Barium Oxide

 

Control Type: Free Access

 

Solubility: 3.*9g/**0g water(*0°C)

 

Combustibility: No special burning explosion characteristic

 

Hazard Label: *3

 

Physical Property:

Colorless Transparent Crystal, White powder.

 

Notes for Storage:

Seal Drying Save.

 

Toxicology:

High poison;

Corrosive;

Maximum allowable concentration: 0.1 mg/m3.

(The standard of the harmful substances in the air of workplace is from the former Soviet Union)

 

Solubility:

Soluble in Water & Carbinol.

(It doesnt completely soluble in water while it absorbs carbon dioxide quickly from the air into carbonate.)

Solubility: 3.*9g/**0g water(*0°C)

Slightly soluble in Ethanol;

Hardly soluble in Acetone.

If absorb carbon dioxide from the air transform into carbonate, which cannot be completely soluble in water.

**0g water dissolved 3.*9g in *0° C.

 

Production Method:

Barium chloride solution & sodium hydroxide takes reaction and precipitation.

 

Detection Method:

AES - Atomic Emission Spectrometry

lAtomic emission spectrometry, under the thermal excitation or electric excitation, uses each element in the atom or ion emission characteristic spectrum to determine the composition of the material, to carry on the qualitative and quantitative elemental analysis method.

lAtomic emission spectrometry is one of the original generations and makes progress in optical analysis. In modern times, it plays an important role in qualitative and quantitative analysis of various materials.

lAdvantages:

1. With simultaneous multi-element detection capability. Determine a variety of elements in one sample.

2. The rapid analysis result. If use the photoelectric direct reading spectrometer, it can quantitative analysis dozens of elements in a few minutes. Without chemical treatment, analysis sample including solid and liquid can be determined directly (arc spark method).

3. Detect the limit low. General lighting source can be up to ***0.1 mg/ml, the absolute value of **0.*1 mg. High frequency inductive coupling plasma (ICP - AES) level detection limit is of ng/ml.

4. Accuracy is higher. Common light sources error is about 5%**0%, the ICP AES is relatively below 1%.

5. Less sample consumption.

6. The ICP originating calibration curve linear wide range can be up to **6 orders of magnitude.

lDisadvantages:

High content analysis accuracy is poorer; Common non-metal elements spectrum, such as oxygen, sulfur, nitrogen, halogen etc., are in the ultraviolet region, general spectrometer cant detect yet; and some non-metallic elements, such as P, Se, Te, etc., due to its high excitation voltage, are with low sensitivity.

lAnalysis methods:

1. The qualitative analysis

Each element of the atom has its own characteristic spectrum, according to the atomic spectrum characteristic spectral line in the elements can determine whether there is the checked element in the sample. Usually we called the element characteristic spectrum intensity bigger line as the elements sensitive line. As long as spectrum sensitive line of a certain element detected in the sample, there is the element can be confirmed. On the other hand, if it wasn't detected, the checked element doesnt exist in the sample, or the content of the checked element under the detection sensitivity.

2. The semi-quantitative analysis

Qualitative spectrochemical analysis always uses spectrographic method, by comparing the sample spectrum with the pure substance spectrum or iron spectrum to determine whether the element there. It is now the most important means of spectral semi-quantitative analysis, which can quickly give roughly the content of the element under test in the sample. And the commonly methods used are the line blackness comparison method and emerge method, etc.

3. The quantitative analysis

Due to the emission spectrum analysis being affected by the fluctuation of the experimental conditions, the spectral line intensity measurement error is bigger, in order to compensate the error caused by fluctuations, usually using internal standard method for quantitative analysis. Internal standard method is to compare the relation of the analysis line and the compared lines intensity with elements content to carry on spectral quantitative analysis method. The compared line chooses called the internal standard line, to provide the marking elements, known as the internal standard element. Internal standard method was put forward by Mr. Geithner about ***5.

AAS - Atomic Absorption Spectroscopy

lAlso called the atomic absorption spectrophotometric method, is a kind of method which is according to the specific material ground state of atomic vapour on the radiation absorption characteristics to carry on the quantitative analysis of the elements.

lAAS used in analyzing the metal elements, and can be used for the direct determination of more than *0 kinds of elements, is an important technology of the determination of minor and trace elements.

lFeatures:

Simple equipment, convenient operation, high sensitivity, good selectivity, and strong anti-jamming capability, high accuracy, fast analysis speed.

Analysis methods: standard curve method, standard addition method

The most commonly used analysis method is the standard curve method, which makes up a series of different concentration of standard solution, by adjusting blank solution zero absorption in the same measurement conditions, according to the standard solution concentration and absorbance to draw the absorbance-concentration standard curve, determine the absorbance of the sample solution, using interpolation method on the standard curve to obtain the measuring elements content in the sample.

lApplication:

Industry, agriculture, light industry, medicine & health care, environmental monitoring and scientific research.

 

Application:

Determination of carbon dioxide from the air chlorophyll ration

Sugar

Animal & Plant oil refining

Beet sugar refining

Clearing agent (boiler water)

Pesticides

Rubber industry

Special soap

Organic synthesis

Barium salt preparation

Soften the water

Glass lubrication

 

Production Method:

 

 

 

Country: China
Model No: Barium Salt Series
FOB Price: 699 / Metric Ton Get Latest Price
Place of Origin: -
Price for Minimum Order: 699 per Metric Ton
Minimum Order Quantity: 100 Ton
Packaging Detail: Professional Package: 25kg/pp bag.
Delivery Time: Within 25 Days After Received the L/C or the Depos
Supplying Ability: 3000 Metric Ton per Month
Payment Type: L/C, T/T
Product Group : Barium Hydroxide

Send a direct inquiry to this supplier

To:

williams < goldway international ltd >

I want to know: