Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Desktop Safety Comprehensive tester AN9640A(F)AN9640B(F)
Next

Desktop Safety Comprehensive tester AN9640A(F)AN9640B(F)

FOB Price

Get Latest Price

1 ~ 8000 / Unit ( Negotiable )

|

1 Unit Minimum Order

Country:

China

Model No:

-

FOB Price:

1 ~ 8000 / Unit ( Negotiable ) Get Latest Price

Place of Origin:

Qingdao,China

Price for Minimum Order:

1 per Unit

Minimum Order Quantity:

1 Unit

Packaging Detail:

wooden case

Delivery Time:

-

Supplying Ability:

200 Unit per Month

Payment Type:

T/T, L/C, D/A, D/P, PayPal

Product Group :

-

Contact Now
Free Member

Contact Person Ainuo

Jinan, Shandong

Contact Now

Product Description

AC Hipot test  
Booster rated output capacity AN***0A(F) **0VA(***0V/**0mA)1  
AN***0B(F) **0VA(***0V/*0mA  
Booster maximum short-circuit current >**0mA  
Output waveform Sine wave, <3%(pure resistance,***0V/1mA),<3%(From empty load to full load)  
distortion and regulation  
Output voltage setting Range **0~***0V  
Resolution 5V  
Accuracy ±(3%×setting**0V  
Frequency setting Range *0Hz/*0Hz  
Accuracy ±0.1%×setting  
Alarming limits setting Current upper-limit 0.*0~*9.*9mA(*0.*0mA for AN***0B/C(F))  
Current lower-limit 0.*0~*0.*0mA  
Compensation current setting Range 0.*0~*0.*0mA, automatic testing, compensation can be set to ON/OFF  
Time setting Range 1~**9s  
Ramp up time range 1~**0s  
Accuracy ±(0.1%×setting*1count  
Breakdown current alarm Range 0.*0~*9.*9mA(*0.*0mA for AN***0B/C(F))  
Accuracy ±(3%×reading*3counts  
Insulation Resistance test  
Rated output capacity 2VA(***0V/2mA  
Output voltage regulation <3%(From no load to full load  
Output voltage ripple <1%  
Output voltage setting Range DC **0Vor***0V  
Accuracy ±(3%×setting*3counts  
Alarming limits setting Resistance upper-limit range 0.0~*9.9 MΩ,**0~***0MΩ(If upper-limit is set to 0, it will not make adjudgment for upper limit )  
Resistance lower-limit range 0.3~*9.9 MΩ, **0~***0MΩ  
Time setting Range 1~**9s  
Accuracy ±(0.1%×setting*1count  
Insulation resistance measurement Range 0.0~*9.9 MΩ, **0~***0 MΩ  
Accuracy ≤**0MΩ: ±(3%×reading*3counts  
 
Remarks:Except **0V and ***0V voltage points, other voltage accuracy are all *0%. Insulation resistance accuracy is under temperature 0~*0℃ ,humidity *0℃/(*0~*5)% RH,otherwise the accuracy will change.  
Ground Bond Resistance test  
No load output voltage <*2V  
Output current setting Range 3~*0A  
Accuracy ±(3%×setting*0.2A  
Current frequency setting Range Sine waveform *0Hz/*0Hz  
Accuracy ±0.1%×setting  
Test time setting Range 1~**9s  
Accuracy ±(0.1%×setting*1count  
Result display mode Ground resistance or voltage  
Ground resistance display mode  
Alarming limits setting Resistance upper-limit range 3A≤output current≤*0A:*0~**0 mΩ  
 
 
Resistance lower-limit range 0~**0 mΩ  
Compensation resistance setting Range 0~**0 mΩ, automatic testing, compensation can be set to ON/OFF  
Ground bond resistance measurement Range *0~**0 mΩ  
Accuracy ±(3%×reading+ 5counts  
Ground voltage display mode:  
Alarming limits setting Voltage upper-limit range *0~***0 mV  
  Voltage lower-limit range 0~***0 mV  
Compensation voltage setting Range 0~***0 mV, automatic testing, compensation can be set to ON/OFF  
Ground bond resistance measurement Range *0~***0 mV  
  Accuracy ±(3%×reading+ *0mV  
DUT power control  
DUT power requirements Leakage current, running power and voltage start test, user shall provide the correct power to safety tester, recommend to use AN*7 frequency conversion power supply  
Input voltage, frequency 0~**0V(phase voltage), *5~*5Hz  
Isolation transformer output voltage ratio Leakage current test 1.*6 times rated voltage  
Running Power test 1.*0 times rated voltage  
Voltage start test 0.*5 times rated voltage  
DUT Capacity Single phase, AN***0A(F) load capacity is 6 KVA  
AN***0B(F)/AN***0C(F) load capacity is 2KVA  
Over current protection Max current *0A, after the over current 5S,automatically cut off the isolation transformer  
Interface  
Remote interface  

Country: China
Model No: -
FOB Price: 1 ~ 8000 / Unit ( Negotiable ) Get Latest Price
Place of Origin: Qingdao,China
Price for Minimum Order: 1 per Unit
Minimum Order Quantity: 1 Unit
Packaging Detail: wooden case
Delivery Time: -
Supplying Ability: 200 Unit per Month
Payment Type: T/T, L/C, D/A, D/P, PayPal
Product Group : -

Send a direct inquiry to this supplier

To:

Ainuo < Ainuo Instrument Co,Ltd >

I want to know: