Product Description
Basic features: 1, the simulator built-in
high-capacity lithium battery, can work long hours; fully charged
can work more than *0 hours (the factory). Because it is a lithium
battery, please try not to over discharge. Please note that the
proper use of the charger, the charger voltage can not be higher
than 4.2V. 2, using *0 universal adapter
for ECG, ECG machine and can be used with a variety of monitors of
lead wires to connect. 3, the charger green
light indicates charging is completed, the more red light indicates
that power is low. 4, increase the low
battery auto shutdown features to protect the lithium battery.
Instructions for use: The simulator can produce the following
waveforms, the first waveform as a code representing 1, the normal
ECG waveform 2, positive and negative triangular waveform Note
Note: 1, the simulator automatically generated after power waveform
a normal ECG waveform. 2, the simulator LED display tubes, when
there is no operation within five seconds, it will
automatically turn off the display to save power. Press any
to display the trigger again. Key
Description:
A
total of four s, followed by selection keys to increase the
key, down key, the Enter key, in addition to a set of key
combinations
Select
:
This
is used to select the parameter to be changed, a total of
four LED tubes to display the four codes represent the content
displayed from left to right,
The
first representative waveform code, the first **4 represents a
parameter to change (the first two are numerical one hundred, the
first three on behalf of ten, on behalf of the first four bits)
Each
one digital tube right lower leg with red highlights, representing
the current position is selected, you can increase and decrease
s to change it. Increase key: When using the Select to
select a good to change the content, use this key parameter
changes. Decrease key: When using the Select to select a
good to change the content, use this key parameter changes. Enter
key: When the parameter change is completed, this will confirm
to confirm changes to the parameters and generate the
corresponding waveform. Key combinations: Press the Select key, and
then press the Enter key, release the Enter key, release the Select
key, then select a key combination represents, press the Enter key
will display different content. The simulator can
produce the following waveforms, the first code represents the
waveform as follows: 1, the normal ECG waveform 2, positive and
negative triangular waveform 3, arrhythmia triangular waveform
simulation 4, square wave, square wave measurement using scanning
speed 5, sine wave, amplitude-frequency characteristic measurement
6, simulated respiratory waveform 7, simulated fetal heartbeat
(non-standard) 8, to set the size of the signal amplitude 9 with
pacing ECG signal *0, can change the width of the bottom of the
triangular wave *1, can change the T-wave amplitude, heart rate,
QRS wave amplitude, QRS wave of the ECG waveform width *2, pacing
signal *3, a triangular wave superimposed sinusoidal 2Hz
Instructions say to use the various waveforms, respectively, the
method of operation: A normal ECG waveform:
★ heart rate setting range
:*****0bpm; (initial value: *0 bpm)
★ signal amplitude fixed. 2,
positive and negative triangular waveforms:
★ Frequency range :*****0bpm;
(initial value: *5 bpm) ★
amplitude range :0.**4Mv (*0:0.1 mV, **0:4 mV);
★ 2 modes, Mode 1: positive
waveform Mode 2: Negative waveform; through a combination of keys.
3, arrhythmia waveforms: ★
Frequency range :*****0bpm; (initial value: *0 bpm)
★ amplitude range :0.**4Mv
(*0:0.1 mV, **0:4 mV); ★ 2
modes, Mode 1: the next big wave, Mode 2: Big wave on top. Through
a combination of keys. 4, square wave:
★ Frequency range: 0.1Hz**0Hz
(*0:0.1 Hz **0:*0 Hz); (Initial value: 1 Hz)
★ amplitude range :0.**4Mv
(*0:0.1 mV, **0:4 mV); 5, sine wave:
★ Frequency range :****0Hz;
(initial value: *0 Hz) ★
amplitude range :0.**4Mv (*0:0.1 mV, **0:4 mV);
★ superimposed on the waveform
DC component, the range is 0.1mV*3mV (*0:0.1 mV, **0:4 mV);
★ Through the combination of
keys, select the need to change the parameters, Mode 1: Frequency;
Mode 2: DC component superimposed
(*0:0.1 mV, **0:4 mV); 6,
simulated breathing waveforms:
★ Frequency range :****0 beats
/ minute. (Initial value: *0 bpm)
★ Please note that at this time
ignored ECG. 7, simulated fetal heart rate (extensions)
★ Frequency range :*****0bpm;
(initial value: **0 bpm) 8, the signal amplitude settings:
★ amplitude range: 0.1mV*4mV
(*0:0.1 mV, **0:4 mV); (initial value: **0)
★ Please note that this setting
will affect the amplitude of ECG waveforms, in addition to all
waveforms. 9 with pacing ECG signal
★ 2 operating modes: Mode 1:
pulse waveforms; Mode 2: pacing pulses with ECG; through a
combination of keys. ★
Frequency range :*****0bpm; (initial value: *0)
★ pulse waveform width:
1ms***0ms; (initial value: *0ms)
★ pulse waveform width
adjustment, the impact of the pulse waveform in both modes.
★ pulse waveform amplitude of
the signal amplitude is set by the eight affected. *0 width
adjustable triangular waveform
★ waveform amplitude: 0.1mV*4mV
(*0:0.1 mV, **0:4 mV); ★
Frequency range: Fixed *0 / S ★
width adjustment range: 2ms***0ms; (initial value: **0ms) *1 Analog
ECG waveform ★ This waveform
There are four operating modes, Mode 1: You can change the T-wave
amplitude; Mode 2: Set the waveform frequency; Mode 3: Set QRS
waveform amplitude; Mode 4: Set the width of the QRS complex,
between operating modes sequentially through key combination to
convert. ★ T wave amplitude
setting range: 0.1mV*2mV; (initial value: *0)
★ waveform frequency setting
range :*****0bpm; (initial value: *5)
★ QRS waveform amplitude range:
0.1mV*4mV; (initial value: 1mV)
★ QRS waveform width range:
*0ms***0ms; (initial value: *0ms) *2, pacing signal (pulse
waveform) ★ This waveform of
two kinds, namely positive and negative directions of pulse
waveform ★ units of 0.1 ms
★ amplitude size needs to be
set in the signal amplitude (8) set the amplitude size *3, a
triangular wave superimposed sinusoidal 2Hz
★ triangular waveform amplitude
can be set
Country: |
China |
Model No: |
SKX-2000G
|
FOB Price: |
193 / Unit (Negotiable)
Get Latest Price
|
Place of Origin: |
Xuzhou, Jiangsu, China |
Price for Minimum Order: |
193 per Unit |
Minimum Order Quantity: |
1 Unit |
Packaging Detail: |
Bubble wrap drop resistance |
Delivery Time: |
1-2 days can be shipped |
Supplying Ability: |
984 Unit per Week |
Payment Type: |
Western Union |
Product Group : |
ECG monitoring equipment category
|