Product Description
Both C arm and X-ray located. Directly, exactly and
conveniently locating, or equip with B- ultrasound device, and it
will both B-ultrasound and X-ray locating.
The
mission success rate of broken calculi once can be improved because
spherical motion small C arm shock wave source system could choose
the best angle.
Low energy, minimally invasive, therapy is
effective, and it could compatibility with good shock wave source,
more choices for clients.
High quality X ray image system and high
definition monitor, the level of image resolution ratio is upper
than national standard.
Control system could infinitely variable
control shock wave energy, triggering frequency range of choice is
wide, equip with talkback system, it could be control both table
side and separate room.
Sphere of activities range of shock wave
source is much wider.
Caution: Main function of this equipment is use
for therapy calculus, other function couldn’t compare with
professional device or equipment.
Environmental temperature:
*5½*5„ƒ
Relative humid:
*5½*5%
Atmospheric pressure:
*6½**6kPa
Power requirements: AC
3N~**0V±*0% *0±1Hz, PW≤5kW (excluding
film)
Water requirements: Dematerialized
water
Main room ≥4m×4m×2.5m
Auxiliary room ≥2m×4m
X-ray proof of the main room(standard details
should consult the demand of GB***6.*2)
Discharging range: EH: *2~*8kV EM:
5~*1kV
Capacity storage: EH:
5~*4J EM:
*3~**8J
Parameter of second focus of shock
wave
Shock wave front
≤0.5mS
Shock wave width
≤1mS
Focus range of second focus of shock wave:
radial±7mm¼axial±*2.5mm¼ˆEH¼‰
radial±7.5mm¼axial±*0mm¼ˆEM¼‰
Height of second focus ≥**0mm
Shock wave generator move spherical motion round
focus area
Shock wave generator is compatible both with
electromagnetic and electrohydraulic.
X-ray localization
(Both C arm and X-ray located)
X-ray tube voltage: *0~**0kV
X-ray tube currency ≤5mA (only
fluoroscopy)
X-ray image definition
≥*4LP/mm
High resolution intensifier and high definition
CCD vidicon
B-ultrasound localization
(Optional)
Axes extension of probe
The localization error may be caused by the probe
makes linear movement relative to the focus is
within ±2mm
The localization error may be caused by the
probe makes annular movement relative to the focus is within
±2mm
The measurement error between the probe surface
and the second focus is within ±2mm
Separate room control and table side control
system
Plan and right angle high definition
monitor
Infinitely variable control of
energy
Discharge frequency range is between0.3~2
second/time and adjust freedom
International control system, long period and
gentle touch
*-D mechanical movement: X≤**0mm, Y≤**0mm,
Z≤**0mm
Angle of rotation between treatment bed and level,
downward *0°
Dip angle of treatment bed, outward
*0°
Maximum capacity of the table ≥**5kG
C arm, small C arm movement cause localization error of second
focus ≤±2mm。
Country: |
China |
Model No: |
HD.ESWL-V
|
FOB Price: |
10 ~ 30 / ( Negotiable ) (Negotiable)
Get Latest Price
|
Place of Origin: |
china |
Price for Minimum Order: |
10 |
Minimum Order Quantity: |
1 Set |
Packaging Detail: |
wooden |
Delivery Time: |
30 days |
Supplying Ability: |
500 Set per Month |
Payment Type: |
T/T |
Product Group : |
- |