Product Specification

Accuracy : 0.05%,0.1% AC Voltage : 0-1050V AC Current : 0-24A DC Voltage : 0-1050V DC Current : 0-22A Communication : RS232 PC software : optional Harmonic : 2-31th Resistance : 0-2M oHm Dot frequency square wave outputã : 1kHz-1000kHz Current coil : 200A,600A,1000A Warranty : 3years

Product Description

GF6018A CLAMP TYPE MULTIMETER CALIBRATOR

The equipment is compliance with national verification regulation: JJG124-2005 Ammeter, voltmeter, power meter and resistance meter verification rules and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics
 

FEATURES

  • It can be semi-automatic or manual inspection of analog multi meter, clamp type current meter, all kinds of electric meter, (voltmeter, ammeter, frequency meters, resistance meter) basic error
  • The equipment can be generated with 2-31 harmonic wave, harmonic number, order, amplitude and harmonic phase of fundamental wave can be programmed
  • Power amplifier working frequency range is 40Hz-1KHZ, has a good linear. Current amplifier is constant current source; voltage amplifier is constant voltage source. Because of light weight, this device is more suitable for field use
  • With RS-232 interface, this device is controlled by PC through the PC software (optional), can be automatic or manual inspection, and the results are processing and management
  • Has a non-volatile memory, it can store 500 pieces of the raw data of tested meter, for access and upload
 

PARAMETERS

Electrical parameters  
Power supply Single phase AC 220V±10% or 110V±10%, 50/60HzAC
AC Voltage output  
range 200mV, 400mV, 2000mV, 4000mV,
20V, 100V, 200V, 500V, 1000V
Range 20V-1000V Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 200mV-4000mV Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS (1000V not included)
Fineness 5×10-5
AC Current Output  
Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
Range 0.2A-20A  Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 2mA-40mA   Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS
Fineness 5×10-5
Frequency Output  
Range 45-65Hz
Fineness 0.001Hz
Accuracy 0.01Hz
Harmonic Wave  
Times 2-31
Extent 0-20%
Each harmonic phase fineness  0.01·N (N is  harmonic order)
DC voltage output  
Range 200mV, 400mV, 2000mV, 4000mV,
20V, 40V, 100V, 200V, 400V, 1000V
Load capacity 20W
Adjustable range 0-110% FS (1000V not included)
Adjustable fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.03%RD+0.02%FS)
Ripple wave ≤1% FS
DC current output  
Range 20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A
Load capacity 20W
Adjustable Range 0-110% FS (1000V not included)
Adjustable Fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.06%RD+0.04%FS)
Ripple wave ≤1% FS
Resistance box  
Range 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ,
0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ
Fineness 0.02%
Range 0-2kΩ, 0-20kΩ, 0-200kΩ  
Range 0-2kΩ  Adjustable Range 0-100%FS
Accuracy ±(0.12%RD+0.08%FS)
Range 0-200Ω,0-2MΩ Adjustable Range 0-100% FS
Accuracy ±(0.3%RD+0.2%FS)
Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ  
Range 2kΩ-4kΩ Adjustable Range 5%-100%FS
Accuracy ±(0.12%RD+0.08%FS)
Range  200-400Ω,
2MΩ-4MΩ
Adjustable Range 5%-100% FS
Accuracy ±(0.3%RD+0.2%FS)
Clamp meter range  
200A Accuracy ±0.2%
600A Accuracy ±0.5%
1000A Accuracy ±1%
Dot frequency square wave output 
Range 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
Square wave amplitude 4.5V
Setting accuracy 5×10-5
Mechanical parameters  
Dimension (L×W×H) (mm) 440x360x160
Weight (kg) 12
Environmental conditions 
Operating temperature 20°C±10°C
Relative humidity ≤85%RH

Contact Us

Contact Person :Mr. Francis

Company:BEIJING GFUVE ELECTRONICS CO., LTD.

Address:Chaoyang, Beijing, Beijing, China,

To,

Mr. Francis < BEIJING GFUVE ELECTRONICS CO., LTD. >
I want to know:

More Products From Other Suppliers

Battery Nail-Penetration Test Machine Battery Nail-Penetration
PI2STAR Intelligent Wireless Sensor for Pump Condition Monitoring PI2STAR Intelligent
Three Phase Power Analyzer GFUVE FU2200A 96*96mm Multifunction Power M Three Phase Power Analyzer
Borescopes, Endoscopes, Inspection Video Camera, Industrial Borescopes Borescopes Endoscopes
Ultrasonic Testing KDE Probe Ultrasonic Testing KDE
DP1-020097-BB01 dia 0.20mm length 9.70mm test probe and super thin with gold plated test needle DP1-020097-BB01 dia 0.20mm
Brand New Keysight E5052B SSA Signal Source Analyzer, 10 MHz to 7 GHz, In Stock Brand New Keysight E5052B
HV wireless current sensor ammeter recorder GF2018 HV wireless current sensor
Professional Compression Tester kit Cylinder Leakage tester Professional Compression
watt-hour meter test bench watt-hour meter test bench
Vibration Analyzer DC-23 Vibration Analyzer DC-23
ZL10-1 weighing device ZL10-1 weighing device
GTS8202 split type bi-function coating thickness gauge by GuoOu GTS8202 split type
PERX Peroxide Test 100 (Fast and easy determination of Peroxide residuals) PERX Peroxide Test 100
Thermal shock chamber Thermal shock chamber
Stanford Research System SR560 Low Noise Preamp IN STOCK 2/10/2014 Stanford Research System