FOB Price
Get Latest Price|
1 Case Minimum Order
Country:
China
Model No:
Model:BD-8000
FOB Price:
Place of Origin:
China
Price for Minimum Order:
-
Minimum Order Quantity:
1 Case
Packaging Detail:
Carton
Delivery Time:
-
Supplying Ability:
1000 Case per Year
Payment Type:
T/T
Product Group :
China
Contact Person Shuang
Qingshuihe, Shenzhen, Guangdong
Product Name | Infusion Pump |
Product Model | Model: BD****0 |
Infusion Pump Mechanism | Peristaltic Mechanism |
Flow Rate Range | *****0 ml/h |
Bolus Rate | ***0 ml/h |
Infusion Increment | 0.1 |
Water-proof Classification | IP*1 |
Infusion Mode | 1. Rate Mode; 2. Time Mode; 3. Body Weight Mode; |
Rate Mode | Rate: *****0 ml/h |
Time Mode | 1. Time: 1minute****0minutes 2. Vol.: 0.1ml****9.9 ml |
Body Weight Mode | 1. Body Weight: 0.1kg***0.0 kg 2. Drug: 0.1mg***9.9 mg 3. Liquid: 0.****9.9 ml 4. Dose: 0.*****9.9 (The maximum value is restricted to body weight, drug, liquid, dose and unit) 5. Dose Unit: mg/kg/h or ug/kg/min |
KVO Rate | Adjustable Range: 1ml/h*5.0 ml/h (The pump will infuse at the KVO rate when there is an occlusion alarm) |
Preset Volume Range | 0.*****9.9 ml |
Preset Time Range | ***9 hours *9 minutes |
Accumulated Infusion Volume Displayed | 0.*****9.9 ml |
Infusion Accuracy | ± 5% |
Power Supply | AC**0V***0V, allowable error± *0%, *0/*0Hz or D. C. 7.4v, relative error *5%, **0% (rechargeable lithium battery, ***0mAh) |
Maximum Power Consumption | Max*5VA, running more than 2 hours at the rate of *5ml/h after being fully recharged. |
Battery Charge | When infusion pump is connected to AC power, turn on the Power and the battery will start charging automatically (about ***4 hours to charge fully). |
Fuses | Double **0V 2A |
Displayed Information | Flow rate, preset volume, accumulated volume, Battery capacity, AC power symbol, infusion completion, occlusion, air bubbles, bed No. and pressure value etc. |
Status Indication Information | Stop, Run, Bolus, KVO |
Alarm Information | Over, occlusion, air bubbles, low pressure, installation error of infusion pipe, abnormal1, abnormal2, drops error and serious low battery. |
Air Bubble Detection | At the rate of **0ml/h, the smallest bubbles that can be detected are 0.**5ml of volume. |
Infusion Pressure | Maximum pressure is **0kPa, occlusion gate value is
*9.2kPa***7.2kPa. The longest time to give occlusion alarm is 2 minutes at rate of *5ml/h. And at rate of 5ml/h is 5 minutes. |
Maximum Size of Outer Shell | **5mm× **0mm× **5mm (length× width× height) |
Maximum Weight | < 3.0 kg |
Classification | Class II, Type BF |
Work Mode | Continuous Operation |
Outer Shell Material | ABS Plastic |
Operating Conditions | Environment temperature: 5degrees celsius-**0degrees
celsius; Air pressure: (*****6)Kpa; Relative humidity: *0%~*0% |
Storage Conditions | Environment temperature: **0degrees celsius-**0degrees
celsius; Air pressure: (*****6)Kpa; Relative humidity ≤ *5%; Non-corrosive gas and well-ventilated room. |
Applicable Infusion Pipes | National standardinfusion pipes |
Applied Standard | GB/T*******8 GB********5 GB***6.*****7 GB ***6.******5 GB***9.1 GB/T*********3 YY********3 |
Country: | China |
Model No: | Model:BD-8000 |
FOB Price: | Get Latest Price |
Place of Origin: | China |
Price for Minimum Order: | - |
Minimum Order Quantity: | 1 Case |
Packaging Detail: | Carton |
Delivery Time: | - |
Supplying Ability: | 1000 Case per Year |
Payment Type: | T/T |
Product Group : | infusion pump |