Product Description
Product Description: Standard parameter: ECG, RESP, NIBP, SpO2,
TEMP, PR Adopt independent modular design to resist vibration and
electromagnetic interference Seven-lead ECG waveforms, Oxygen
waveform and Respiratory waveform display on demand Apply to adults
, children and newborn monitoring. *2.1'' big screen true color TFT
display , supporting external CRT Adopt digital SpO2 design to
resist campaign interference and weak perfusion Protection against
interference from defibrillation and electrosurgical knife *0
seconds ECG waveforms playback, Maximum **0 hours trend information
saving and recalling Monitoring, diagnosis and surgery three models
can be switched. Widely use in Medicine, surgery, operating
theatres, ICU / CCU, obstetrics and gynecology, pediatrics,
emergency department. Arrhythmia , ST section and ECG waveform
anomaly can be detected. Build-in high-capacity battery , up to
4hours working time. Build-in printer. Product Parameters 1. ECG
Full Lead: I, Ⅱ, Ⅲ, AVL , AVR, AVF, V1, V2, V3, V4, V5, V6 Gain: 5
mm/mV, *0mm/mV, *5mm/mV, *0mm/mV, *5mm/mV Scanning Speed:
Changeable with three grades of *2.5mm/s, *5 mm/s, *0 mm/s Band
width : 0.*5Hz***0Hz(3dB) Heart Rate: Scope : *5 times/minute to
**0 times/minute Accuracy : ±1 time /minute Alarm: heart rate
alarm: alarm delay < *2s 2. SpO2 Detection Scope : 1%***0%
Resolution : 1% Accuracy: ±2% *0%***0%; ±3% *0%**9% Detection scope
of pulse- rate: *0times minute to**5 times/minute Pulse- rate
Accuracy : ±2% within *****5times/minute Arbitrary set the alarm
ceiling and alarm limit 3. NIBP(Non-invasive blood pressure) Theory
: Electric Oscillator Cuff gassing time : less than *5 seconds
Adults and children model Detection Method: Automatic Detection
cycle: 1minute to **0mintes Manual Detection at any time according
to the needs of patients Detection Accuracy: Static pressure:
0.5Kpa(±3mmHg) Protection: Inflatable overvoltage protection and
Measurement protection Arbitrary set the alarm ceiling and alarm
limit 4. RESP (Respiration ) Detection Method : Chest Impedance
Method Scope: 5times/minute***0times/minute Accuracy: ±2times/
minute (*5times/minute**0times/minute) ±5times/minute
(*1times/minute***0times/minute) Alarm Preferences:
Continuous-tuning step: 1time/minute Arbitrary set the alarm
ceiling and alarm limit 5. Temperature Channel: single or double
path (T1, T2) Unit : ℃ or ℉ Scope: *5℃**5℃ Accuracy: ±0.1℃
Resolution:0.1℃ 6. Software Display Model: Large font model,
tendency concurrent model, model with seven-lead on the same
screen, standard model and complete model. 7. Print Taking paper
speed: *5 mm/s Can print **3 any waveform at the same time