Product Description
Patient monitor model:CMS***0 Multi-parameter Monitor Features: 1.
Color TFT Screen, waveform up to 8 channels 2. Light and portable
with build-in rechargeable battery 3. UP to *0 kinds of monitor
parameters 4. Arrhythmia analysis, pace-marker detection and S-T
Segmentanalysis 5. *2 hour storage and review of trend grams and
tables, *0 second review of olographic Wavefo RMS. 6. Built-in
recorder(option) 7. All-round monitor of adult, pediatric and
neonatal. 8. Electrosurgical unit and defibrillation protected 9.
Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature,
Pulse rate *0. Option parameters: EtCO2, CO, IBP, Thermal Printer
ECG 1. *-lead or *-lead selectable 2. Input: *-lead: RA; LA; RL;
LL; V or R; L; N; F; C 3. Lead selection: I; II; III; avR; avL;
avF; Vx 4. sweep speed: *2.5mm/s, *5mm/s, *0mm/s 5. Accuracy:about
1 Bpm or 1% up and down, whichever is greater 6. Protection:
Withstand ***0VAC/*0Hz voltage in isolation against electrosurgical
and defibrillation 7. Calibration signal: 1mV within 5% deviation
8. Operation modes: Diagnostic, Monitor, Surgery 9. Alarm range:
Adult: *****0bpm *0. Pediatric/Neonatal: *****0bpm *1. Alarm range:
*2.0mV~2.0mV *2. S-T detection: YES, Arrhythmia analysis: YES *3.
Alarm: YES, audible and visual alarm, alarm events recallable NIBP
1. Method: Oscillometry 2. Operation modes: Manual/Automatic/STAT
3. Measurement unit: MmHg/KPa selectable 4. Measurement types:
Systolic, Diastolic, Mean 5. Measurement range: Adult: *****0mmHg
6. Over-pressure protection: YES 7. Resolution: 1mmHg 8. Accuracy:
Mean error and standard deviation per ANSI/AAMI SP**0 9. Alarm:
Systolic, Diastolic, Mean SpO2 1. Measurement range: ****0% 2.
Accuracy:about 2% up and down (*0~**0%); 3. 0~*9% unspecified 4.
Alarm range: ****0% Respiration 1. Method: RA-LL impedance 2.
Pediatric/Neonatal: ****0rpm 3. Alarm range: Adult: ****0rpm 4.
Pediatric/Neonatal: ****0rpm 5. Apnea alarm: YES Temperature 1.
Resolution: 0.1 2. Channel: Dual-channel 3. Alarm range: ***0
Option: EtCO2 1. Measurement Mode: Side-stream or mainstream 2.
Measurement range: EtCO2: ***9mmHg 3. Accuracy: CO2 concentration
4. Apnea alarm: YES CO 1. Method: Thermo-dilution 2. Measurement
range: CO: 0.***0 lit. /min. IBP 1. Channel: 2 channels 2. Pressure
transducer: Sensitivity: 5( mV/V/mmHg) 3. Transducer sites: ART,
PA, CVP, RAP, LAP, ICP 4. Alarm range: **0~**0mmHg