Heating gradient of the furnace:
*0℃/min, the maximum heating ratio of the column temperature is
*5℃/min
For VOC the retention time is <*0
sec, for SVOC which is <*0 sec.
Sampler injection repeatability is
<3%RSD peak area, retention time error is <1%RSD
Data base of >****0 kinds of elements, of which the green ones
>***0 kinds.
Electronic Mode
Plug and play controller, furnace and
detector
Input and GC storage by touch
screen
Displaying all the actual and setting
value of GC parameter
Clients’ parameter setting has
protection function for permission
Furnace temperature controlled
program has multiple kinds of gradient for selections
Carrier gas controlled program has
multiple grades
Switch control of relay and solenoid
valve of time order
All the parameters for detectable
probe displaying in single screen
Two electric pressure
controllers
Atmospheric pressure and temperature
compensation
EPC controlled resolution ratio
reaches 0.1Kpa
Micro processer control
Digital signal of the detector
output
Universal voltage : **0VAC,
filtering and changing via linear
Source: **6W(*8VDC ×7AMPS)
DC electrical source available
Basic Features:
Plug and play module design
Multiple standards application
specific profiles
Compact electronic furnace and
shockproof design
Colorful touch screen controlled
design
Continuous operation by internal
GC
Patent digital signal process
Internal diagnostic program
Electric pressure controller
precision: 0.**1KPaf
Furnace resists **5℃ environmental
temperature
Temperature gradient of furnace is
*0℃/min, heating speed reaches to *0℃/min in maximum, moment
heating ratio can reach *5℃/sec, temperature controlled precision
is ±0.**1°C
Fast cooling (**5 to *0℃). ≤4
min,
Compact and light design
Water resistant briefcase size
(*2×*0×*1cm)
Weight: about *0kg
One or two compact gas cylinder
(purchase independently available)
Detector:
Accuracy: <*0%, precision: 5%
RSD
Both independent and combined
installations are available
0.1℃ resolution ratio, maximum
temperature is **0℃
Realize *4 digit output via USD port
EPC pressure controlled precision:
0.1KPa
Available Detector:
FID******-flame ionization detector
(**0×***9g limit)
PID******-photo ionization detector
(*0×***9g limit)
TCD*****-thermal conductivity
detector (1×***6g limit)
HID******-hydrogen ionization
detector (**0×***9g limit)
NPD*****- nitrogen-phosphorus
detector (*0×***9g limit)
TID*******-thermal detector (*0×***9g
limit)
ECD******-electron capture detector
(0.1×***9g limit)
Furnace Module:
Temperature resistant up to **5℃
column temperature
Temperature gradient of the furnace
*0℃/min
Fast cooling (**5 to *0℃), ≤4
min,
**0W heating element
Multiple temperature gradient set,
precision is 0.1℃
Appearance size:
*2.5×*0.5×*2.5cm
Single electron sample valve is
available
Source: car inventor (convertor
equipped), external handled rechargeable battery
Sample Injector:
One or two optional
installation
Shunt or nun-shunt calibration, gas
sample needn’t heat
Circular injection tube cooling
Multiple gradient set, precision is
0.1KPa
Equipped with two control
solenoid
Digital Communication:
Two-way connection general data
system
USB digital signal output
Network Connection
GC of operating Windows XP works in
enterprise net compatible network
The computer of ETX structure can be
used in the GC control and data read
Applying the web of Windows network
protocol for web connection
LAN/WAN/VPN remote controlled GC data
read