Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
TY-601  Dielectric Loss Tester Dielectric Loss Tester
Next

TY-601 Dielectric Loss Tester Dielectric Loss Tester

FOB Price

Get Latest Price

800 ~ 5000 / Piece

|

10 Piece Minimum Order

Country:

China

Model No:

TY-601

FOB Price:

800 ~ 5000 / Piece Get Latest Price

Place of Origin:

China

Price for Minimum Order:

800 per Piece

Minimum Order Quantity:

10 Piece

Packaging Detail:

1pcs/wooden box ,

Delivery Time:

7 days

Supplying Ability:

500 Piece per Month

Payment Type:

T/T

Contact Now
Free Member

Contact Person tianyancheng

Guangzhou, Guangdong

Contact Now

Product Specification

  • Brand Name: TYC
  • Usage: Power
  • Phase: Three

Product Description

II Performance
1. The tan delta tester adopts Fourier transform digital filtering technology to measure capacitance, dielectric loss and other parameters. The test result has high precision and is convenient to realize automatic measurement.
2. The instrument adopts frequency conversion technology to eliminate *0Hz power frequency interference on site, so that reliable data can be measured even under the environment of strong electromagnetic interference.
3. Full-touch large LCD, easy to operate.Full touch LCD screen, large full graphics UI, each process is very clear, operators do not need additional professional train and can use directly .The whole process can be measured at the touch of a finger.
4. Data storage: equipped with calendar chip and large-capacity memory internally, it can save test results at any time, view historical records at any time and print out.The current time and storage time can be displayed and printed at any time.
5, scientific and advanced data management: instrument data can be exported through the U disk, view and manage data  through special software from PC.
6. The instrument is easy to operate and the measurement process is controlled by the microprocessor. As long as the appropriate measurement method is selected, the data measurement can be completed automatically under the control of the microprocessor.
7. Integrated model, with standard capacitor and high voltage power supply, convenient for field test and reduce field wiring.
8, the instrument measurement accuracy is high, can meet the oil dielectric loss measurement requirements, so only equipped with standard oil cup, and special test line can achieve oil dielectric loss measurement.
9. It has reverse wiring low-voltage shielding function. In the case of **0kV CVT bus grounding, it can measure the dielectric loss of *0kV reverse wiring of C*1 without removing wires
*0.  Able to do AC voltage withstand test .t.It is convenient for PT and CT to do ac pressure withstand test twice and **0V low voltage system to do pressure withstand test.
*1. It can identify the frequency of external high-voltage power supply from *0Hz to *0Hz, and it is allowed to use power-frequency power supply or serially connected resonant power supply for high-capacity high-voltage dielectric loss test.
*2, with CVT test function, can achieve CVT self-excitation test, can set high voltage/current, low voltage/current four protection limits, to ensure personal and equipment safety.
*3. Equip PC interface. One PC can control *2 pcs of devices. It can be integrated into the comprehensive high voltage test vehicle to realize measurement, data processing and report output
*4, grounding protection function, when the instrument is ungrounded or not well grounded, the instrument will not enter the normal procedure and will not output high voltage
*5. Over-current protection function, the instrument will not be damaged when the test product is short circuit or breakdown.
*6 electric shock protection function, when operator get an electric shock accidentally, the instrument will cut off the high voltage immediately, to ensure operators safety
 
 
III Thechnical parameter
 
Accuracy       Cx:                    ±reading ×1%*1pF
Tgδ    :           ±reading×1%*0.****0
Anti-interference index  Frequency conversion ,still can get the above accuracy in **0% interference  
Capacitance range       internal high voltage     3pF****0pF/*0kV       *0pF1μF/0.5kV
External high voltage   3pF1.5μF/*0kV           *0pF*0μF/0.5kV
resolution                                                                                      MAX 0.**1pF4 significant digits
tgδ range unlimitedresolutionv0.**1% capacitance ,inductance, resistance can be identified automatically  
Test currant range5μA5A
Internal high voltage    setting voltage range0.5*0kV
Max output current**0mA
Voltage lifting modeSet voltage as will, such as ***3V
Test frequency Set single frequency in ****0HZ, such as *8.7Hz
*0±0.1Hz to *0±*0Hz  Set automatical dual frequency conversion as will
*0±0.1Hz to *0±*0Hz  Set automatical dual frequency conversion as will
Frequency accuracy    ±0.*1Hz
External high voltage   Max test current during front connection 5 Apower frequency or frequency conversion ****0Hz
Max test current during reverse wiring  *0kV/5Apower frequency or frequency conversion****0Hz
power    **0V**0VAC*0Hz±1%mains power or generator power
PC interface   standard RS**2 interface USB interface(Store data  in USB automatically)
Printer      mini thermal printer
Ambient temperature   **0*0
Relative humidity        <*0%
Dimension **0mm***7mm***0mm
N.W*8kg
 
 

Country: China
Model No: TY-601
FOB Price: 800 ~ 5000 / Piece Get Latest Price
Place of Origin: China
Price for Minimum Order: 800 per Piece
Minimum Order Quantity: 10 Piece
Packaging Detail: 1pcs/wooden box ,
Delivery Time: 7 days
Supplying Ability: 500 Piece per Month
Payment Type: T/T
Product Group : Transformer test series

Send a direct inquiry to this supplier

To:

tianyancheng < Hubei Tianyancheng Electricity Equipment MFG CO., LTD >

I want to know: