Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 9 Million Importers & Exporters globally.
Join Now, its Free |
Book call on your favorite time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Amazon Services

Cable Alliance Holding

2 Melnikov Street , Yekaterinburg,,Russia

View Phone Number

Free Member

Product Specification

Brand Name : HOLDCAB Insulation Material : - Type : - Application : - Conductor Material : - Jacket : -

Product Description

HoldCab® TM cables meet the Russian and interstate standards of the Customs Union GOST R 55025-2012, GOST 31996-2012, GOST 1508, GOST 31565-2012.
Cables' design, technical specifications and service characteristics meet the international IEC 60502-2 standard (pt.1,2).
The Holding has developed special types of power and pilot cables under TM HoldCab brand, with different types of insulation, overall shielding, fire rating.
TM HoldCab cables are resistant to low temperatures (operation up to minus 60°C, laying up to minus 30 °C); resistant to salt mists, and have increased oil resistance. They may be used in explosive atmosphere as well.
TM HoldCab cables are produced within the import substitution program to substitute cable make ups produced by the foreign manufacturers. In this the Holding designs are in no way inferior to the best foreign analogs.
TM HoldX combines a group of cables for solar panels with increased resistance to external influences. This group of cables is designed for the transmission of electricity in solar power systems with a nominal DC voltage of 1.5 kV.
The HoldX solar cables are highly resistant to external factors and can be laid outdoors without protection from solar radiation. The wide operating temperature range (from minus 60°C to 60°C above zero) allows the use of HoldX cables in different climatic zones.
Cables are resistant to: solar radiation, high humidity, ozone exposure, rain exposure, frost and dew effects, oils, dynamic impact of dust, effects of ammonia, diluted solution of acids (3%) and alkalis (sodium hydroxide 1%), special media (pollutants-sulfur dioxide; carbon monoxide, nitrogen oxides, hydrocarbons (oil vapor), widespread cleaning solutions), fungus.
The products comply with the requirements of the Russian and international standards. They are approved by the largest power generating companies. The cables are included in STO (company standard) 1.1.1.01.001.0902-2012 Cable products for nuclear power stations.

APPLICATION

Installation at the temperature up to -35 °C without preheating.
  • Long-term permissible heating temperature of current-conducting conductors in service is 105 °C.
  • It increases the cable performance on 15-20%, comparing to the BBG cable type.
  • Great service characteristics at Increased flexibility of a cable low temperatures up to -65 °C.
  • The installation of cables is possible at the temperature up to -35 °C without preheating, allowing to use it in areas with cold climate.
  • The permissible cable temperature at short circuit is 250°C, which greatly increases the reliability of the entire
    cable system.
Resistance to aggressive environments.
  • Increased cable stability (high resistance of rubber to moisture eliminates the risk of ionization breakdown of insulation).
  • Cables are allowed to be laid in explosive areas of all classes.
  • Increased flexibility of a cableEasier installation of the cable in constrained conditions.
Increased fire safety.
  • The use of ethylene-propylene rubber as the insulation of power cables, due to the elasticity of this material, allows the cable to be operated with increased payloads (connections to engines, pumps).
  • Cables comply with requirements of all categories of LPBW, including LPBW1 (combustible mass volume is 7 l/ m flame application time 40 minutes), category A GOST R IEC 60332.

     

Contact Us

Contact Person :Ms. Beldina

Company:Cable Alliance Holding

Address:2 Melnikov Street , Yekaterinburg,, Russia,

To,

Ms. Beldina < Cable Alliance Holding >
I want to know:

More Products From Other Suppliers

Tinned copper wire silicon 10 AWG AWG UL 3135 Tinned copper wire silicon
wire and cable wire and cable
IEC60502 Copper Conductor PVC Insulation NYY Cable VV Power Cable IEC60502 Copper Conductor
Electric Wires Electric Wires
WIRE & CABLE EXPO VIETNAM 2016 WIRE & CABLE EXPO
COPPER CONDUCTOR XLPE/PVC INSULATION  PVC JACKET NEXANS(CHINA) COPPER CONDUCTOR XLPE/PVC
Spade Terminal without Stud Spade Terminal without Stud
booster cable/ light duty booster cable/ light duty
Low vontage wire and cable Low vontage wire and cable
energy cables energy cables
yellow green grounding wire yellow green grounding wire
cable & wire cable & wire
Hand-held Explosive Trace Detector Hand-held Explosive Trace
227IEC01 pvc cable for house using 227IEC01 pvc cable for
Leaky cable Leaky cable
xlpe insulated high voltage power cable xlpe insulated high voltage