Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Ractopamine Rapid Test (Urine)

Ractopamine Rapid Test (Urine)

FOB Price

Get Latest Price

|

Minimum Order

Place of Origin:

Shanghai,China

Price for Minimum Order:

-

Minimum Order Quantity:

1000 Piece

Packaging Detail:

10 tests/kit or bulk as request

Delivery Time:

3 work days

Supplying Ability:

60000000 Acre per Day

Payment Type:

T/T, L/C, D/A, D/P, Western Union, Money Gram, PayPal, Other

Contact Now
Free Member

Contact Person Ms. Yohey

No.1998 Yanggao Road, Shanghai, Shanghai

Contact Now

Description

1. INTENDED USE

Quicking Ractopamine Rapid Test is a competitive immunoassay for the semi-quantitative detection of the presence of Ractopamine residue in urine

Cut-off:   5 ppb

Assay Time:  5 **0 min

 

2. PRINCIPLE OF THE ASSAY 

Quicking Ractopamine Rapid Test is based on competitive lateral flow immunochromatographic assay. The RAC-conjugate in the test zone will capture the immuno-gold (colloid gold-RAC antibody conjugate), when there is very little dissociative RAC in the samples. A visible red test band indicates a negative result when the control line (C zone) shows that the card is valid. The test band (T zone) will be not visible if RAC is present in concentration of ppb and above which explains a positive result. 

3. KIT COMPONENT

*0×foil pouches each containing one cassette, one pipette and a desiccant

Product Manual

4. TEST PROCEDURE

Collect clean urine directly for running the assay. If the sample is cloudy, do a centrifugation to make the urine clean for use. 

Take out the cassette from the foil pouch and place it horizontally.

Gradually drip 3 drops of sample extraction into the sample hole “S”.

Interpret the result in 5 - *0 minutes. Result after *0 minutes is considered as invalid.

5. INTERPRETATION OF RESULTS

 

PositiveOnly one clear band in zone indicates a positive result. Positive shows that the concentration of Ractopamine is at or above ppin the sample.

Negative: The presence of both clear band in zone and zone. 

Invalid: No colored band appears in C zone.

6. SPECIFICITY

The results are negative when the test is applied to detect **0 ppm of Clenbuterol, Trenbolone-acetate, Chloramphenicol, Aminoglycosides, Beta-Lactams, Macrolides, Quinolones, and Sulfonamides.

The results is negative when the test is applied to detect 1 ppm of Salbutamol.

7. STORAGE

The kit can be stored at room temperature (2**0°C). The test kit is stable through the expiration date (*8 months) marked on the foil pouchDO NOT FREEZE. Do not store the test kit in direct sunlight.