Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
A-1A-F Series Thermal Cutoff Thermal Fuse

A-1A-F Series Thermal Cutoff Thermal Fuse

FOB Price

Get Latest Price

( Negotiable )

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

-

Minimum Order Quantity:

1000 Piece

Packaging Detail:

Cartons

Delivery Time:

35 days

Supplying Ability:

-

Payment Type:

T/T

Contact Now
Free Member

Contact Person Mr. Harold

4F, No.4, Ln. 560, Zhongzheng Rd, Xindian Dist, New Taipei City, Taiwan

Contact Now

Description

A*1A-F Series Thermal Cutoff Thermal Fuse 

The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection current. The tolerance according to IEC****1 is from *0 to**0.(With Japan Electrical Appliance and Material Law; on the other hand, they must function in the tolerance range of ±7).

 

A*1A-F Series
Model No Rated functioning temp.   (Tf) Fusing-off temperature Holding temperature(Th) Maximum temp. limit (Tm) Rated current
(Ir)
Rated voltage(Ur) Safety approval RoHS Compliace
UL CUL VDE PSE CCC EK
A**1A-F **2℃ *8±2℃ *6℃ **0℃ 1A **0Vac
A**1A-F **5℃ **2±3℃ *5℃ **0℃ 1A **0Vac
A**1A-F **5℃ **0±3℃ *7℃ **0℃ 1A **0Vac
A**1A-F **0℃ **6±2℃ **2℃ **0℃ 1A **0Vac
A**1A-F **5℃ **1±3℃ **5℃ **0℃ 1A **0Vac
A**1A-F **8℃ **5±2℃ **8℃ **0℃ 1A **0Vac
A**1A-F **0℃ **5±3℃ **0℃ **0℃ 1A **0Vac

Rated functioning temperature(Tf) The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection curret.The tolerance according to IEC****1 is from *0 to**0.(With Japan Electrical Appliance and Material Law,on the other hand,they must function in the tolerance range of ±7.).
Fusing(cut)-off temperature The fusing-off temperature indicates value measured in silicon oil with a temperature increased by 0.**1 per minute and a detective current **0mA or less.
Holding temperature(Th) The maximum temperature at which a thermal Cutoff will not cause a change in state of conductivity to open circuit while conducting rated current for **8 hours. This rating is required by safety standards based on IEC****1.
Maximum temperature limit(Tm) The maximum temperature at which a Thermal Cutoff can be maintained for *0 minutes without reclosing. This rating is required by safety standards based on IEC****1.
Rated current(Ir) The allowable maximum current which a Thermal Cutoff is able to carry.
Rated current(Ur) The allowable maximum voltage which a Thermal Cutoff is able to be applied.
 
 
 

Send a direct inquiry to this supplier

To:

Mr. Harold < Honest-Well Co., Ltd. >

I want to know: