Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell covid-19 igg/igm test kit

Sell covid-19 igg/igm test kit

FOB Price

Get Latest Price

1.5 ~ 2 / Piece

|

Minimum Order

Place of Origin:

No. 38 Dongfang Road, Wenzhou, Zhejiang, China

Price for Minimum Order:

Minimum Order Quantity:

10000 Piece

Packaging Detail:

carton

Delivery Time:

15day

Supplying Ability:

80000 Piece per Day

Payment Type:

T/T, L/C

Contact Now
Free Member

Contact Person Mr. zhibin

38 Dongfang Road, Wenzhou, Zhejiang

Contact Now

Description

MATERIALS Materials Provided
1)Foil pouches, with test cassettes and disposable droppers
2)Assay buffer
3)Instruction for use
Materials Required But Not Provided
1)Specimen collection container
2)Lancet
3)Centrifuge (for plasma only)
4)Timer DIRECTIONS FOR USE Allow the test, specimen, buffer and/or controls to reach room temperature (****0°C) prior to testing.
1. Remove the test cassette from the foil pouch and use it within one hour. Best results will be obtained if the test is performed immediately after opening the foil pouch.
2. Place the cassette on a clean and level surface.
 ForSerum or Plasma   specimen:
· To use a dropper: Hold the dropper vertically, draw the specimen to thefill line(approximately *0mL), and transfer the specimen to the specimen well (S), then add 2 drops of buffer(approximately *0mL), and start the timer.
· To use a pipette: To transfer*0mLof specimen to the specimen well(S), thenadd 2 drops of buffer(approximately *0mL), and start the timer
ForVenipuncture Whole Blood specimen:
· To use a dropper: Hold the dropper vertically, draw the specimen about1 cm above the fill lineand transfer1 full drop(approx. *0μL) of specimen to the sample well(S). Then add2 drops of buffer(approximately *0mL) and start the timer.
· To use a pipette: To transfer 10 mL of whole blood to the specimen well(S), then add 2 drops of buffer(approximately *0mL), and start the timer
ForFingerstick Whole Blood specimen:
· To use a dropper: Hold the dropper vertically, draw the specimen about1 cm above the fill lineand transfer1 full drop(approx. *0μL) of specimen to the sample well(S). Then add2 drops of buffer(approximately *0mL) and start the timer.

  • To use a capillary tube: Fill the capillary tube and transfer approximately *0mL of fingerstick whole blood specimen to the specimen well (S) of test cassette, then add 2 drops of buffer(approximately *0mL) and start the timer. See illustration below.
  • Wait for the colored line(s) to appear.Read results at *5 minutes.Do not interpret the result after *0 minutes.
Note: It is suggested not to use the buffer, beyond 6 months after opening the vial.
 

Send a direct inquiry to this supplier

To:

Mr. zhibin < Wenzhou Astock Biotechnology Co., Ltd >

I want to know: