2014 New product neutral grounding resistor, power distribution ngr for generator  protection
Next

2014 New product neutral grounding resistor, power distribution ngr for generator protection

FOB Price

Get Latest Price

2500 ~ 9800 / Set ( Negotiable )

|

1 Set Minimum Order

Country:

China

Model No:

MRD-BJ

FOB Price:

2500 ~ 9800 / Set ( Negotiable ) Get Latest Price

Place of Origin:

-

Price for Minimum Order:

2500 per Set

Minimum Order Quantity:

1 Set

Packaging Detail:

Inner packing: PE film bag or as per client's request; Out packing: corrugated carton or wooden

Delivery Time:

25-30 working days against deposit or L/C

Supplying Ability:

70 Set per Month

Payment Type:

PayPal, Money Gram, Western Union, L/C, T/T

Contact Now
Free Member

Contact Person Ms. Anastasia

No.118 West Fuxing Road, Baoding, Hebei

Contact Now

Product Specification

  • Brand Name: MINGRUI
  • Resistance value:1-2000 ohm
  • Altitude:up to 3500m, for higher alititude application, please consul
  • Power frequency:50/60Hz
  • Application:Indoor application
  • Current:2-2000A
  • Enclsoure:common steel sheet/ hot dip galvanized steel sheet

Product Description

Brief Introduction to product
 
 

 
With neutral grounding resistance is installed, when nonmetal grounding, the current flowing through grounding point and neutral would be much less than that when metal grounding. Meanwhile sound phase voltage rise is lowered a lot and zero-sequence voltage is half of that when single-phase metal grounding. Therefore, adopting neutral grounding via resistance could decrease transient overvoltage when single-phase grounding, and eliminate arc flash hazards like transient overvoltage and some resonant overvoltage, and moreover it could adopt simple relays to quickly locate the fault line and clear it up.
Mingrui has outstanding technical researching team and superior equipments, specially concentrate on research & development, production, sales and service of neutral grounding series products of power distribution system. The transformer neutral grounding resistance we developed and produced is applicable to 6~*5KV power distribution grid of cable lines in cities, large industrial enterprises, factories, airports, seaports, subway and etc. as well as 0.*6KV system in mine digging and 0.4kv/6kv/*0kv system in power plants.
 
Applicable Standards
 
The design of the product complys with the following standards:
 
IEC**6    Dry-Type Power Transformer
IEC***1    Experimental Technique of High Voltage
IEC****9:***1 Enclosure Protection Degree (IP code)
IEEE******2  Technique Terms and Experiment of Neutral Grounding Device
IEC****1    Insulation Co-ordination of Transmission and Distribution Device of High Voltage
 
The Characteristeic of the Product
 
 
 
3.1 Adopted high quality imported stainless steel or domestic stainless steel electric heating metal material,
the product operates safely and reliably with the advantages of high conductivity, high temperature coefficient, corrosion resistance, thermostability, good oxidation resistance, high tensile strength, resistance value stability and etc.
 
 
3.2 The device also could be applied in medium power distribution system. When transformer is angle-connected, independent grounding transformer could be installed with which the neutral point and resistance are connected.
3.3Resistance value could be designed from 1ohm to ***0ohm and current from 1A to ***0A
 
 
3. 4 The cabinet could be installed indoor or outdoor. As the cabinet body is corrosion-resistant and of high protection grade, made from stainless steel plate or painted cold rolled steel plate.
3.5 The counting function could be added to the device, which records times of resistance grounding.
3.6 Isolated switch could be added which convenient examination and repair and so does temp. or humidity controller.
3.7 Intelligent monitor is at customers option, which could monitor un-balanced current of neutral point when resistance cabinet is in normal operation, temp. of resistance panel, and temperature of inside cabinet, measure transient current and records grounding times when single-phase grounding happens, reserve communication interface which could send monitored and recorded to master-control room so as to let operating people get the information in the first time.
 
Model Meaning
 
Typical Technology Parameters
 
Various resistors could be designed as per customers requirement, value ranging from 1Ωto ***0Ω. Current allowed to flow through is  from 1A~***0A and the flowing time is *0s,*5s,*0s,*0s and 2h.
 
Schematic Diagram for Wire Connection
 
6.1 The transformer adopts star connection with neutral leading-out wire ,connected as in figure 5.
6.2 If the neutral is triangle-connected, neutral grounding resistor is grounded by grounding transformers. Connection is as in figure 6
 
Service Condition
 
8.1 Generally applicable to outdoors,used in the system of *0 Hz and *0 Hz.
8.2 The altitude shall not exceed ***0m.
8.3 Ambient temperature : **0~**0℃,Relative humidity:*5%
8.4 Wind pressure is not higher than **0Mpa (equal to wind velocity *4m/s) 
8.5 Earthquake intensity : 8 degree
8.6 Thickness of coated ice: *0mm
8.7 Grade of air pollution: not higher class
8.8 The air at the installation site shall be free from inflammable/ explosive/ corrosive gas,and conductive dust.
8.9 As resistor is heating device. The temperature will rise high when using it. Therefore, some space should be left around the the place where the resistor is installed, avoiding being influenced by external heating source. Please pay close attention to this.
 
Notice for Ordering
 
Please let us know the parameters below.
9.1 Rated Voltage of System: (kv)
9.2 Current Value Allowed to Flow Through in Short Time:(A)
9.3 Nominal Resistance Value:(Ω)
9.4 Whether current transformer needed or not (CT)?
  Ratio and capacity and composite error of it is required.                 
9.5 Wire-in and wire-out modes are for choice:
a. top-in and bottom-out,    b. bottom-in and bottom-out,  
c.side-in and side-out,      d. side-in and bottom-out.
9.6  Allowable Time of Current Flowing Through in Short Time:(S)
9.7 Material of resistor cubicle,protection grade of cubicle(IP), the color code and installation location.  
9.8 Optional Devices: Recorder of Grounding, Controlling Device of Temp. and Humidity.
 

Country: China
Model No: MRD-BJ
FOB Price: 2500 ~ 9800 / Set ( Negotiable ) Get Latest Price
Place of Origin: -
Price for Minimum Order: 2500 per Set
Minimum Order Quantity: 1 Set
Packaging Detail: Inner packing: PE film bag or as per client's request; Out packing: corrugated carton or wooden
Delivery Time: 25-30 working days against deposit or L/C
Supplying Ability: 70 Set per Month
Payment Type: PayPal, Money Gram, Western Union, L/C, T/T
Product Group : Neutral protection devices

Send a direct inquiry to this supplier

To:

Ms. Anastasia < Baoding Mingrui Optoelectronics Technology Co., Ltd >

I want to know: