Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Arc suppression coil, electrical distribution ASC equipment for neutral protection, neutral grounding reactor
Next

Arc suppression coil, electrical distribution ASC equipment for neutral protection, neutral grounding reactor

FOB Price

Get Latest Price

5000 ~ 10000 / Set ( Negotiable )

|

1 Set Minimum Order

Country:

China

Model No:

MRD-XHZ

FOB Price:

5000 ~ 10000 / Set ( Negotiable ) Get Latest Price

Place of Origin:

-

Price for Minimum Order:

5000 per Set

Minimum Order Quantity:

1 Set

Packaging Detail:

wooden case

Delivery Time:

25-30 working days against deposit or L/C

Supplying Ability:

30 Set per Month

Payment Type:

PayPal, Money Gram, Western Union, L/C, T/T

Contact Now
Free Member

Contact Person Ms. Anastasia

No.118 West Fuxing Road, Baoding, Hebei

Contact Now

Product Specification

  • Brand Name: MINGRUI
  • System voltage:6-66kv
  • Altitude:up to 2000m, for higher altitude application, please consult
  • Application:Dry type only for indoor application, oil immersed type coul

Product Description

Overview
 
In power system of ***6KV, when capacitive current associated with single phase ground fault excess *0A (It is *0A in ***0KV cable circuit system), arc suppression coil device should be adopted to prevent arc grounding, remove earth fault and improve power supply quality.
 
MRD-XHZ Arc-Suppression Coil with Adjustable Tuning Compensation Device employs standard industrial computer system, bus-organization, multilayer PCB and full-color LCD screen to provide system with stable operation, visual display, strong anti-interference capability, perfect parameter settings and information query function.
 
MRD-XHZ Arc-Suppression Coil with Adjustable Tuning Compensation Device adopts ****0KV voltage grade and is widely used in transformer substations of large factories and mines.
 
Features

  1. Controller adopts industrial computer platforms, dual-CPU framework and multilayer PCB processing to ensure stable and reliable operation
  2. With full-color LCD screen, the running state, system capacitive current, neutral voltage, neutral current, out-of-resonance degree, residual current and fault-times of single-phase can be displayed, set and inquired conveniently
  3. The adjusting range is wide, between ****0% rated current and also accurate and quick
  4. Embedded high voltage grounding line selection module employs residual incremental method and active power method making the line selection accurately and quickly
  5. Equipped with RS**2 and RS**5 communication interface, our product can communicate with supervising computer to achieve signal teleportation
  6. Our product can realize acoustic alarm of single-phase earth fault
  7. Equipped with standard parallel printer, our product can finish data printing and ground information printing
  8. Our product possess one system controlling two sets device function, namely, two sets of arc suppression coil in the same system can transform automatically along with the system operation
 
Unit configuration
 
  1. Grounding Transformer
  2. Arc suppression coil with adjustable turns
  3. Load switch
  4. Micro-computer controller
  5. Thyristor(SCR) and trigging device
  6. Disconnect or
  7. Damping resistor
  8. Voltage transformer
  9. Zinc oxide lightning rod
  10. High-voltage current limiting fuse
  11. Cabinet( indoor or outdoor)
  12. control panel
  13. Small current earthing wire line
 
Operation conditions
  1. Ambient Temp: **5℃~**5
  2. Relative Humidity: Less than *5%
  3. Altitude: less than ***0m (if excess, please specially indicate)
  4. No corrosive gas around the site and no conductive dust
  5. No sever shocked movement around the site
  6. Micro-computer controller screen is to be installed in master control of the station. Grounding transformer, ASC device and damping resistor are to be installed outdoor or indoor with good ventilation
 
Technical performance index
  1. Voltage class: 6KV,*0KV,*5KV
  2. Measuring error of capacitive current: less than 2%
  3. The residual current at single-phase earth fault: less than 5A
  4. Fault response time less than *0ms
    1. Controller power requirement: A Alternating current **0V, rated frequency *0Hz
                             A Direct current **0V/**0V, rated frequency *0Hz
  1. communication interface: RS**2/RS**5
 
Ordering data
  1. System voltage grade: 6KV, *0KV, *5KV
  2. Arc Suppression Coil capacity
  3. The capacity of arc suppression coil is determined according to the size of the capacitive current under the single-phase grounding fault and should have a certain margin
  4. The grounding transformer capacity
  5. the quantity of zero sequence current transformer
 
 
Attention!
 
Please ensure good grounding system of the device and make different access to the ground network for the cabinet and the device. In dry areas, the ground network resistance should be measured regularly to make sure the ground resistance less than 4Ω to prevent burning loss.
 

Country: China
Model No: MRD-XHZ
FOB Price: 5000 ~ 10000 / Set ( Negotiable ) Get Latest Price
Place of Origin: -
Price for Minimum Order: 5000 per Set
Minimum Order Quantity: 1 Set
Packaging Detail: wooden case
Delivery Time: 25-30 working days against deposit or L/C
Supplying Ability: 30 Set per Month
Payment Type: PayPal, Money Gram, Western Union, L/C, T/T
Product Group : Power factor correction

Send a direct inquiry to this supplier

To:

Ms. Anastasia < Baoding Mingrui Optoelectronics Technology Co., Ltd >

I want to know: